●商品名:radware Alteon 5208 [ODS-VL2, PN: 1900046001]×2台セット!(#J3-725)です。 ●写真の通りの商品です。
●login:admin、password:pass。 ●開封歴無し。Warranty/Guarantee Stickerは破損無し。
●CPU: 1 * Xeon E3-1230 V2-3.3GHz、RAM: 32GB。
●多少の擦り傷広がった状態。機器起動時は次の状態です。
Version 2.15.1236. Copyright (C) 2012 American Megatrends, Inc.
CASwell, Inc. COB-G501 BIOS v016 (09012015)
Current BIOS : BIOS0
Press 《Del》or 《Tab》to enter setup.
Press 《M》to enter BBS POPUP.
【略】
License for 'droute' software feature is installed already.
License for 'otb' software feature is installed already.
License for 'geo' software feature is installed already.
Software feature 'Geo DB Update' is enabled. #
# # # ##### ###### #### # #
# # # # # # # ## #
# # # # ##### # # # # #
####### # # # # # # # #
# # # # # # # # ##
# # ###### # ###### #### # #
Rebooted because of reset from console.
Booting complete 17:16:18 Mon Aug 11, 2025:
Version 32.4.9.0 from image ID 3, factory default config block.
Start Dispatcher Loop !!!
Verify the inactive BIOS bank
Warning: SPI Configuration Lockdown activated.
reads default BIOS secondery
NOTE: Reading from file /disk/Alteon/config/realIndexes.txt, file does not exist.
NOTE: Reading from file /disk/Alteon/config/groupIndexes.txt, file does not exist.
NOTE: Reading from file /disk/Alteon/config/virtIndexes.txt, file does not exist.
NOTE: Reading from file /disk/Alteon/config/hagroupIndexes.txt, file does not exist.
Loading management port 1 connectivity...
WBM key is not defined, generating...
2025-08-11T17:16:28+09:00 NOTICE system: temperature ok
2025-08-11T17:16:28+09:00 NOTICE system: All fans are operational
2025-08-11T17:16:28+09:00 NOTICE system: Single Power Supply Status: OK.
..
Self signed certificate, certificate signing request and key added.
Note - HT low memory - change the session capacity to 50
Applying Configuration.....
sh: /etc/lcd/ods_lcd4linux.sh: No such file or directory
Enter password:
2025-08-11T17:16:38+09:00 INFO appsvc: Cavium SSL accelerator detected
2025-08-11T17:16:38+09:00 NOTICE mgmt: Image version 32.4.9.0
2025-08-11T17:16:38+09:00 NOTICE mgmt: RSA host key generation starts
2025-08-11T17:16:38+09:00 NOTICE mgmt: RSA host key generation completes
2025-08-11T17:16:38+09:00 NOTICE mgmt: RSA server key generation starts
2025-08-11T17:16:38+09:00 NOTICE mgmt: RSA server key generation completes
2025-08-11T17:16:38+09:00 NOTICE mgmt: RSA server key is being saved to Flash ROM,
please don't reboot the box immediately.
2025-08-11T17:16:38+09:00 CRIT system: The MP CPU Utilization has reached above 80%
2025-08-11T17:17:08+09:00 ALERT system: Warm Start
Enter password:
2025-08-11T17:17:31+09:00 NOTICE system: The MP CPU Utilization have fallen below 70%
The default admin password must be changed at first login
Enter new admin password:
Re-enter admin password:
New admin password accepted.
Applying Configuration....
New admin password applied and saved successfully.
Switch is set to active config block.
System Information at 17:18:16 Mon Aug 11, 2025
Time zone: Asia/Tokyo (GMT offset +09:00)
Memory profile is Default
Alteon Application Switch 5208XL
Switch is up 0 days, 0 hours, 1 minute and 59 seconds.
Last boot: 17:16:17 Mon Aug 11, 2025 (reset from console)
Last apply: 21:07:38 Thu Oct 6, 2022
Last save: 10:36:26 Fri Oct 7, 2022
MAC Address : 2c:b6:93:3d:**:**
Hardware MainBoard No|Rev : ODSVL2-MB | C.C16
Hardware DB No : Not Available
Hardware Serial Number : 4170****
Note - When the measured temperature inside the switch EXCEEDs
the anomaly threshold at 90 degree Celsius or the critical
temperature at 97 degree Celsius different syslog messages
will be generated.
Software Version 32.4.9.0 Image ID 3, active configuration.
HA State: NONE
Mode of operation: by Name
2025-08-11T17:18:16+09:00 NOTICE mgmt: Admin password changed from Console
------------------------------------------------------------------
[Main Menu]
info - Information Menu
stats - Statistics Menu
cfg - Configuration Menu
oper - Operations Command Menu
boot - Boot Options Menu
maint - Maintenance Menu
apropos - Look for cli commands pattern [global command]
diff - Show pending config changes [global command]
apply - Apply pending config changes [global command]
save - Save updated config to FLASH [global command]
revert - Revert pending or applied changes [global command]
exit - Exit [global command, always available]
>> Standalone ADC - Main#
2025-08-11T17:18:16+09:00 NOTICE mgmt: boot config block changed
2025-08-11T17:18:16+09:00 NOTICE mgmt: admin login on Console
>> Standalone ADC - Main# info
------------------------------------------------------------------
[Information Menu]
sys - System Information Menu
l2 - Layer 2 Information Menu
l3 - Layer 3 Information Menu
slb - Layer 4-7 Information Menu
bwm - Bandwidth Management Information Menu
security - Security Information Menu
link - Show link status
port - Show port information
swkey - Show enabled software features
transceiver - Show GBICs information
dump - Dump all information
>> Standalone ADC - Information# sys
------------------------------------------------------------------
[System Menu]
snmpv3 - SNMPv3 Information Menu
mgmroute - Show management static ip route information
general - Show general system information
ps - Show power supply information
fan - Show system fan information
temp - Show system temperature information
sslchip - Show SSL chip information
time - Show date and time
log - Show last n (or 500) syslog messages
syncstat - Show sync status on peer switches
mgmt - Show management port information
capacity - Show switch capacity information
encrypt - Show switch encryption licenses
user - Show current user status
idbynum - Show current Id by Number mode
disk - Show current Disk Allocations
geo - Show geo location database update status
hwhealth - Show hardware health monitoring data collection status
dump - Dump all system information
>> Standalone ADC - System# dump
===============================
CLI Command /info/sys/general:
================================
System Information at 17:24:40 Mon Aug 11, 2025
Time zone: Asia/Tokyo (GMT offset +09:00)
Memory profile is Default
Alteon Application Switch 5208XL
Switch is up 0 days, 0 hours, 8 minutes and 22 seconds.
Last boot: 17:16:17 Mon Aug 11, 2025 (reset from console)
Last apply: 21:07:38 Thu Oct 6, 2022
Last save: 10:36:26 Fri Oct 7, 2022
MAC Address : 2c:b6:93:3d:**:**
Hardware MainBoard No|Rev : ODSVL2-MB | C.C16
Hardware DB No : Not Available
Hardware Serial Number : 4170****
Note - When the measured temperature inside the switch EXCEEDs
the anomaly threshold at 90 degree Celsius or the critical
temperature at 97 degree Celsius different syslog messages
will be generated.
Software Version 32.4.9.0 Image ID 3, active configuration.
HA State: NONE
Mode of operation: by Name
================================
CLI Command /info/sys/log:
================================
Last 200 syslog messages (if available):
Showing 200 latest lines of 2635 syslog messages.
【略】
================================
CLI Command /info/sys/mgmt:
================================
---------------------------------
Management port one information:
---------------------------------
Speed Duplex Link
----- ------ -----
0 0 down
MAC address:
2c:b6:93:3d:**:**
Interface information:
172.21.242.241 255.255.0.0 172.21.255.255
Gateway information:
172.21.255.254 Health Status: Down
================================
CLI Command /info/sys/mgmroute/ipv4/dump -E:
================================
Management IPv4 static routes:
=================================
CLI Command /info/sys/mgmroute/ipv6/dump -E:
=================================
Management IPv6 static routes:
=================================
CLI Command /info/sys/snmpv3/dump :
=================================
Engine ID = 80:00:07:50:03:2C:B6:93:3D:**:**
usmUser Table:
User Name Protocol
-------------------------------- --------------------------------
adminmd5 HMAC_MD5, DES PRIVACY
adminsha HMAC_SHA, DES PRIVACY
v1v2only NO AUTH, NO PRIVACY
vacmAccess Table:
Group Name Prefix Model Level Match ReadV WriteV NotifyV
---------- ------ ------- ------------ ------ ---------- ---------- ----------
v1v2grp snmpv1 noAuthNoPriv exact iso iso v1v2only
admingrp usm authPriv exact iso iso iso
vacmViewTreeFamily Table:
View Name Subtree Mask Type
-------------------- ------------------------------ -------------- ---------
iso 1 included
v1v2only 1 included
v1v2only 1.3.6.1.6.3.15 excluded
v1v2only 1.3.6.1.6.3.16 excluded
v1v2only 1.3.6.1.6.3.18 excluded
vacmSecurityToGroup Table:
Sec Model User Name Group Name
---------- ------------------------------- -------------------------------
snmpv1 v1v2only v1v2grp
usm adminmd5 admingrp
usm adminsha admingrp
snmpCommunity Table:
Index Name User Name Tag
---------- ---------- -------------------- ----------
snmpNotify Table:
Name Tag
-------------------- --------------------
snmpTargetAddr Table:
Name Transport Addr Port Taglist Params
---------- ---------------------------------------- ---- ---------- ---------------
snmpTargetParams Table:
Name MP Model User Name Sec Model Sec Level
-------------------- -------- -------------------- --------- ---------
>> Standalone ADC - System#
●使用されていた商品ですが、全機能を検証する環境が無い為、それ以上の動作は未確認です。
●「電源が入らない」以外は、現状・ノークレーム扱いでの出品とさせて頂きます。
●電源ケーブル等、付属品は何もありません。
●写真をご参照の上、ご入札のほど、宜しくお願いします。
●送料は下記の「120サイズ」(2台1セットあたり)となります。
●運輸業者は当方で決めさせていただきます。
●上記の発送サイズは2台1セットの場合です。複数同時発送の場合の送料はこちらからご連絡いたします。
●中古のダンボールを使用する事より実際の発送サイズが異なる場合がございます。ご了承下さいませ。
●東京都江戸川区西一之江の倉庫にてのお渡しも可能です。
●その場合は、無梱包お渡しとなります。
●営業時間は月曜日~金曜日、AM10:00~PM18:00となります。
●第1.3.5土曜日のみ、11:00~15:00に限り、営業致します。
●第2.4土曜日・日曜日・祝日は休みになります。
●こちらからのご連絡は平日昼間のみとなります。
●また、お取引後の評価ですが不要のお客様が多い為にこちらからは入れておりま
せん。
●評価が必要なお客様は取引メッセージにてのご連絡をお願い致します。
|